Nature CommunicationsNeurosciencePeer-reviewed journal article
Lowering the Thermal Noise Barrier in Functional Brain Mapping with Magnetic Resonance Imaging
Luca VizioliiD, Steen MoelleriD, Logan Thorne DowdleiD, Mehmet AkçakayaiD, Federico De MartinoiD, Essa S. YacoubiD, Kǎmil UǧurbiliD
Abstract
Functional magnetic resonance imaging (fMRI) has become one of the most powerful tools for investigating the human brain. However, virtually all fMRI studies have relatively poor signal-to-noise ratio (SNR). Here we introduce a novel fMRI denoising technique, which suppresses noise that is indistinguishable from zero-mean, Gaussian-distributed noise. Thermal noise, falling in this category, is a major source of noise in fMRI, particularly, but not exclusively, at high spatial and/or temporal resolutions. Using 7-Tesla high-resolution data, we demonstrate improvements in temporal-SNR, the detection of stimulus-induced signal changes, and functional maps, while leaving stimulus-induced signal change amplitudes, image spatial precision, and functional point-spread-function unaltered. We also show that the method is equally applicable when using supra-millimeter resolution 3- and 7-Tesla fMRI data, different cortical regions, stimulation/task paradigms, and acquisition strategies. This denoising approach improves key metrics of functional activation detection while preserving spatial precision.
- organism: human
- assay: multiome
- research focus: dimensionality reduction
- research focus: benchmarking
- approach: statistical model
- Citations
- 167
- FWCI
- 12.80
- Field percentile
- top 1%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- NORDIC Increases the Sensitivity and Preserves the Spatiotemporal Precision of fMRI Responses
Logan Thorne Dowdle, Luca Vizioli, … Kǎmil Uǧurbil·bioRxiv·Aug 26, 2021
- Evaluating the effect of denoising submillimeter auditory fMRI data with NORDIC
Lonike K. Faes, Agustín Lage‐Castellanos, … Federico De Martino·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
Abraham B. Beckers, Gerhard S. Drenthen, … Dániel Keszthelyi·NeuroImagePeer-reviewed·Sep 3, 2023
- Improving the temporal accuracy of functional Magnetic Resonance Imaging
Niels Janssen, Juan A. Hernández-Cabrera, Laura Ezama Foronda·bioRxiv·Sep 5, 2016
- Not all noise-reduction methods for fMRI preprocessing are created equal
Marie‐Eve Hoeppli, Martin Alexander Garenfeld, … Robert C. Coghill·bioRxiv·Feb 8, 2022
- Multi-echo Acquisition and Thermal Denoising Advances Precision Functional Imaging
Julia Moser, Steven M. Nelson, … Damien A. Fair·Imaging NeurosciencePeer-reviewed·Dec 16, 2024