bioRxivBioengineering
Computed Tomography of Polymeric Biomedical Implants from Bench to Bedside
Abstract
Implanted biomedical devices require porosity to encourage tissue regeneration. However, characterizing porosity, which affects many functional device properties, is non-trivial. Computed tomography (CT) is a quick, versatile, and non-destructive way to gain 3D structural information. While optimization of CT for polymeric devices has been investigated at the bench on high-resolution micro-CT (CT) scanners, pre-clinical and clinical systems cannot be tuned the same way, given an overriding objective to minimize ionizing radiation exposure to living tissues. Therefore, in this study we tested feasibility of obtaining structural information in pre-clinical systems and CT under physiological conditions. The size of resolved features in porous structures is highly dependent on the resolution (voxel size) of the scan. Lower resolution underestimated porosity and overestimated pore size. With the homogeneous introduction of radiopaque nanoparticle contrast agent into both biopolymers and synthetic polymers, devices could be imaged in the hydrated state, even at high-resolution. Biopolymers had significant structural changes at the micro-scale post-hydration, including a mean increase of 130% in pore wall thickness that could potentially impact biological response. Through optimizing devices for medical imaging, CT has the potential to be a facile way to monitor devices from initial design stages through to clinical translation.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In vivo Biomedical Imaging of Immune Tolerant, Radiopaque Nanoparticle-Embedded Polymeric Device Degradation
K. Pawelec, J. M. L. Hix, … E. Shapiro·bioRxiv·Oct 26, 2023
- Device Design and Diagnostic Imaging of Radiopaque 3D Printed Tissue Engineering Scaffolds
M. Delemeester, K. Pawelec, … E. Shapiro·bioRxiv·Feb 26, 2024
- Incorporating Radiopacity into Implantable Polymeric Biomedical Devices for Clinical Radiological Monitoring
K. M. Pawelec, E. Tu, … E. Shapiro·Advanced Healthcare MaterialsPeer-reviewed·Mar 13, 2023
- Radiopaque Implantable Biomaterials for Nerve Repair
K. M. Pawelec, J. M. L. Hix, E. M. Shapiro·bioRxiv·Jan 5, 2023
- Material Composition and Implantation Site Affect in vivo Device Degradation Rate
Kendell M. Pawelec, Jeremy M.L. Hix, … Erik M. Shapiro·Communications MaterialsPeer-reviewed·Jul 24, 2026
- In Situ Volumetric Imaging and Analysis of FRESH 3D Bioprinted Constructs Using Optical Coherence Tomography
J. W. Tashman, D. J. Shiwarski, … A. W. Feinberg·bioRxiv·Jun 30, 2021