bioRxivBioengineeringPreprint
Evaluation of Iodine-Based Contrast Agents for Ex Vivo Micro-CT Imaging of Porcine Hearts: An Application to Cardiac Conduction System Imaging
M.V.N. PradeepiD, Shuvashis Das GuptaiD, Yi LiiD, Sami KauppineniD, Mikko FinniläiD, Timo LiimataineniD
Abstract
Purpose: This study compares two iodine-based contrast agents, iodine in ethanol (I2E) and aqueous solution of potassium triiodide (I2KI), in optimizing high-resolution, contrast-enhanced micro computed tomography imaging (micro-CT) of the cardiac conduction system (CCS) in porcine hearts. The study evaluates their relative efficacy in enhancing tissue contrast and anatomical delineation, aiming to improve CCS visualization for advanced cardiac research. Methods: Dissected porcine hearts were stained with I2E or I2KI for contrast enhancement and scanned with micro-computed tomography. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and volumetric shrinkage were evaluated. Additionally, qualitative visualization of CCS-related anatomical landmarks, such as the sinoatrial node (SAN), atrioventricular node (AVN), and Purkinje fibres, was performed, along with assessment of artefact occurrence and sample integrity. The efficacy of the contrast agents was also determined by segmenting the regions of interest corresponding to the CCS from micro-CT images. These were then further validated against histology. Results: I2E provided superior CNR, fewer artefacts, and preserved sample integrity, enabling smooth post-processing and histological sectioning. I2KI staining produced higher soft-tissue signal intensity and faster stain saturation (day 2) than I2E (day 3). However, I2KI exhibited leaching and introduced substantial staining artefacts. I2KI also exhibited structural disintegration, which, in turn, compromised downstream processing. Conclusion: These results suggest that I2E is a viable alternative to I2KI for CCS micro-CT imaging when sample preservation and downstream analyses are essential, whereas I2KI may be preferred for rapid, high-intensity staining where tissue integrity is less critical.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Micro-CT: A reversible contrast-based protocol for non-destructive imaging of cardiac morphology in an avian model.
Joshua Durrans, Nicola Aberdein, … Mari Herigstad·bioRxiv·Jul 15, 2026
- High-resolution 3-dimensional micro-CT imaging of the nucleus pulposus using a novel contrast agent
Madison M. Buckles, Abdulkadir Nur, … Mohammad Y. Ansari·JOR SpinePeer-reviewed·Oct 7, 2025
- Optimizing large organ scale micro computed tomography imaging in pig and human hearts using a novel air-drying technique
N. Pallares-Lupon, G. S. Ramlugun, … R. D. Walton·bioRxiv·Jul 29, 2021
- Optimising neural contrast and minimising tissue shrinkage in dragon lizard brains: buffered Lugol's iodine versus phosphotungstic acid for contrast-enhanced μCT
Fernando Navea, J. Roy Black, … Jenna Margaret Crowe-Riddell·bioRxiv·Oct 20, 2026
- High resolution micro-CT imaging in mice stroke models: from 3D detailed infarct characterization to automatic area segmentation
Raquel Pinto, Jan Matula, … João R. Gomes·bioRxiv·Feb 2, 2022
- A Simple Nuclear Contrast Staining Method for MicroCT-Based 3D Histology Using Lead(II) Acetate
Brian Metscher·Journal of AnatomyPeer-reviewed·Nov 2, 2020