Analytical ChemistrySystems BiologyPeer-reviewed journal article
Super-resolution mass spectrometry enables rapid, accurate, and highly-multiplexed proteomics at the MS2-level
Anton N. KozhinoviD, Alex N. T. JohnsoniD, Konstantin O. NagornoviD, Michael StadlmeieriD, Lance Martin, Loı̈c DayoniD, John CorthésyiD, Martin WühriD, Yury O. TsybiniD
Abstract
In tandem mass spectrometry (MS2)-based multiplexed quantitative proteomics, the complement reporter ion approaches (TMTc and TMTproC) were developed to eliminate the ratio-compression problem of conventional MS2 level approaches. Resolving all high m/z complement reporter ions ([~]6.32 mDa spaced) requires mass resolution and scan speeds above the performance levels of Orbitrap instruments. Therefore, complement reporter ion quantification with TMT/TMTpro reagents is currently limited to 5 out of 11 (TMT) or 9 out of 18 (TMTpro) channels ([~]1 Da spaced). We first demonstrate that a Fusion Lumos Orbitrap can resolve 6.32 mDa spaced complement reporter ions with standard acquisition modes extended with 3-second transients. We then implemented a super-resolution mass spectrometry approach using the least-squares fitting (LSF) method for processing Orbitrap transients to achieve shotgun proteomics-compatible scan rates. The LSF performance resolves the 6.32 mDa doublets for all TMTproC channels in the standard mass range with transients as short as [~]108 ms (Orbitrap resolution setting of 50 000 at m/z 200). However, we observe a slight decrease in measurement precision compared to 1 Da spacing with the 108 ms transients. With 256 ms transients (resolution of 120 000 at m/z 200), coefficients of variation are essentially indistinguishable from 1 Da samples. We thus demonstrate the feasibility of highly-multiplexed, accurate, and precise shotgun-proteomics at the MS2 level.
- Citations
- 14
- FWCI
- 1.29
- Field percentile
- top 24%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
C. D. Kelstrup, K. Aizikov, … J. V. Olsen·bioRxiv·May 28, 2018
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics
Hamish Stewart, Steven R. Shuken, … Steven P. Gygi·bioRxiv·Feb 26, 2026
- Expanding Targeted Instrumentation for Discovery Applications: Complement Reporter Ion Quantification with a Quadrupole-Ion Trap Instrument
Edward R. Cruz, Alex N. T. Johnson, … Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Aug 6, 2025
- Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.
H. Stewart, D. Grinfeld, … C. Hock·bioRxiv·Jun 2, 2023