bioRxivBioengineeringPreprint
Direct Electrical Detection of sub-aM DNA Concentrations
M. Guo, N. Madaboosi, F. Neumann, M. Nilsson, W. van der Wihngaart
Abstract
Sensors for detecting ultra-low concentrations are limited by the efficient transport of target molecules from large sample volumes to small detection regions. We here report a small-format digital DNA sensor in the shape of a microporous membrane that electrically detects DNA substrates with a concentration as low as 790 zM. This ultra-high sensitivity follows from optimising the mass transport of target DNA to specific receptors on the membrane across multiple spatial scales. mm-sized membranes support the rapid convection of a large sample volume to the detection zone; {micro}m-sized pores ensure that DNA diffusion to the surface-based receptors dominates over convective loss through the pores (low Peclet number), and; at the nm-scale, target-receptor binding dominates over diffusive transport (high Damkohler number). After their efficient capture, the DNA molecules are converted with high specificity into trans-membrane gold nanowires that are detected using a simple, high signal-to-noise, electrical resistance measurement. This sensor design is of interest for detecting low-abundant target molecules without the need for sample amplification or up-concentration, and the mass-transport strategy could be adapted to other surface-based sensing schemes.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Nanowire-based biosensor for short DNA using fluorescent silver nanoclusters
Ivan N. Unksov, Rubina Davtyan, … Heiner Linke·Sensors and Actuators A PhysicalPeer-reviewed·Dec 26, 2025
- Tunable DNA Origami Nanosensors for Detection of Multiscale Spatial Ion Concentration Gradients
Peter E. Beshay, Zachary Osborn-King, … Benjamin A. Walter·ACS SensorsPeer-reviewed·Feb 27, 2026
- Ultra-sensitive water contaminant detection with transcription factor interfaced microcantilevers
Dilip Kumar Agarwal, Tyler J. Lucci, … Vinayak P. Dravid·ACS NanoPeer-reviewed·Feb 24, 2025
- The Origin of Conductive-Pulse Sensing Inside a Nanopore and the Role of Electro-Hydrodynamics
L. Lastra, M. Nguyen, … K. J. Freedman·bioRxiv·Sep 25, 2020
- Ligation-assisted target recycling for DNA nanoswitch biosensors
Vinod Morya, Andrew Hayden, … Ken Halvorsen·bioRxiv·May 20, 2026
- A 3D printed mini-gel electrophoresis system for rapid and inexpensive DNA nanoswitch biosensing
Vinod Morya, Andrew Hayden, … Ken Halvorsen·ACS Measurement Science AuPeer-reviewed·May 21, 2026