Biological reactions often involve macromolecules that undergo substrate-induced conformational changes in under a second, yet capturing these transient states remains challenging. While high-resolution structural techniques such as X-ray crystallography and cryo-electron microscopy (cryo-EM) have advanced our mechanistic understanding of protein-substrate interactions, traditional sample preparation methods are too slow to capture rapid biochemical events. Time-resolved cryo-EM has emerged as a promising approach to visualize structural dynamics on microsecond-to-millisecond timescales, but its widespread adoption has been limited by costly equipment and challenges in achieving rapid mixing, application, and vitrification of samples in a reproducible manner. To address these limitations, we developed "Mix-it-up" (MIU), a modified spray device designed for rapid on-grid mixing and vitrification of cryo-EM samples. By manually applying one sample onto the EM grid, blotting, and subsequently spraying the second sample, we achieve on-grid mixing with a vitrification delay of as low as ~120 milliseconds. We demonstrate MIUs time-resolved capabilities through high-resolution structure determination of mixed samples, pH-induced viral capsid contraction, and ligand-dependent complex formation. These findings establish MIU as a cost-effective, versatile tool for studying rapid biochemical processes and lay the groundwork for future applications to time-resolved cryo-EM.
- Citations
- 3
- FWCI
- 1.09
- Field percentile
- top 24%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A Cryo-EM Grid Preparation Device for Time-Resolved Structural Studies
D. Kontziampasis, D. P. Klebl, … H. D. White·bioRxiv·Mar 4, 2019
- Microsecond melting and revitrification of cryo samples with a correlative light-electron microscopy approach
G. Bongiovanni, O. F. Harder, … U. J. Lorenz·bioRxiv·Sep 14, 2022
- Time-resolved cryo-EM using a combination of droplet microfluidics with on-demand jetting
S. TORINO, M. Dhurandhar, … R. G. Efremov·bioRxiv·Oct 21, 2022
- Visual Biochemistry: modular microfluidics enables kinetic insight from time-resolved cryo-EM
M.-E. Maeots, B. Lee, … R. I. Enchev·Nature CommunicationsPeer-reviewed·Jul 10, 2020
- Time-resolved cryoEM using Spotiton
V. P. Dandey, W. C. Budell, … B. Carragher·Microscopy and MicroanalysisPeer-reviewed·Jul 30, 2020
- Microsecond Time-Resolved Cryo-EM Based on Jet Vitrification
Michal Haubner, Harry M. Williams, … Ulrich Joseph Lorenz·bioRxiv·Nov 21, 2025