Deep learning-based prediction of wall shear stress throughout the cardiac cycle in middle cerebral artery bifurcation aneurysms

Bingyuan BaiiD, Xiajie ZhouiD, Kazunori MiyataiD, Tzu‐Ching ShihiD

Abstract

Background and Objective: Cardiac-cycle wall shear stress (WSS) is relevant to intracranial aneurysm hemodynamic assessment, but transient computational fluid dynamics (CFD) is costly. Existing surrogates use steady-flow priors or joint steady/transient training; here we evaluate the transfer of separately pretrained spatial parameters. This study develops the Steady-to-Transient Estimation of Pulsatile Wall Shear Stress (STEP) framework, a two-stage geometric learning approach for full-cycle WSS prediction. Methods: Using the synthetic AneuG-Flow dataset, Stage 0 pretrained a geometric tokenizer, LaB-GATr backbone, and WSS decoder on 11,656 steady CFD cases. Stage 1 initialized these components from the pretrained model and fine-tuned them end to end using 449 transient training cases, with 72 validation and 57 primary test cases. Waveform embeddings multiplicatively conditioned geometric features across blocks at 80 cardiac-cycle time points. Gaussian curvature was included as an auxiliary geometry feature. Ablations evaluated steady initialization, temporal conditioning, and curvature, with rank-biserial effect sizes and Holm-adjusted p values. A fixed model was also evaluated on 231 additional cases, with registered-geometry overlap audited across stages. Results: On the primary test set, STEP achieved a whole-cycle WSS vector mean absolute error (MAE) of 1.688 Pa and root-mean-square error (RMSE) of 2.877 Pa. Time-averaged WSS, oscillatory shear index, and relative residence time MAEs were 1.040 Pa, 0.00625, and 0.06734 Pa-1, respectively. Steady initialization reduced vector MAE by 27.93% relative to training the same transient architecture from scratch; the complete blockwise conditioning configuration reduced MAE by 8.04% relative to input-only additive conditioning (rank-biserial correlations 0.995 and 0.982, respectively; Holm-adjusted p < 0.001). Curvature yielded a 3.46% reduction without a significant paired effect (adjusted p = 0.0521). The 80-time-point WSS prediction required a mean of 4.169 s (SD 0.063 s). Additional-cohort MAE was 1.712 Pa, but 185/231 geometries matched Stage 0 training, versus 1/57 in the primary test set. Conclusions: STEP demonstrated effective reuse of steady-pretrained spatial parameters for cardiac-cycle WSS prediction under the evaluated synthetic CFD protocol. The strongest controlled gains were associated with steady initialization and the complete temporal-conditioning configuration. The common inlet waveform and cross-stage geometry overlap limit generalization claims.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISWang '19Mazzi '26Bozorgpour '25Lebas '22Roy '26Nandurdikar '26
69% semantic matchBioengineering
H. Wang, T. Krüger, F. Varnik·bioRxiv·Nov 29, 2019