Sign in
NeurosciencebioRxiv
Preprint

Model-based frequency-and-phase correction of 1H MRS data with 2D linear-combination modeling.

Dunja SimičićiD, Helge J. ZöllneriD, Christopher W. Davies‐JenkinsiD, Kathleen E. HupfeldiD, Richard A.E. EddeniD, Georg OeltzschneriD

Abstract

PurposeRetrospective frequency-and-phase correction (FPC) methods attempt to remove frequency- and-phase variations between transients to improve the quality of the averaged MR spectrum. However, traditional FPC methods like spectral registration struggle at low SNR. Here, we propose a method that directly integrates FPC into a two-dimensional linear-combination model (2D-LCM) of individual transients ( model-based FPC). We investigated how model-based FPC performs compared to the traditional approach, i.e., spectral registration followed by 1D-LCM in estimating frequency-and-phase drifts and, consequentially, metabolite level estimates. MethodsWe created synthetic in-vivo-like 64-transient short-TE sLASER datasets with 100 noise realizations at 5 SNR levels and added randomly sampled frequency and phase variations. We then used this synthetic dataset to compare the performance of 2D-LCM with the traditional approach (spectral registration, averaging, then 1D-LCM). Outcome measures were the frequency/phase/amplitude errors, the standard deviation of those ground-truth errors, and amplitude Cramer Rao Lower Bounds (CRLBs). We further tested the proposed method on publicly available in-vivo short-TE PRESS data. Results2D-LCM estimates (and accounts for) frequency-and-phase variations directly from uncorrected data with equivalent or better fidelity than the conventional approach. Furthermore, 2D-LCM metabolite amplitude estimates were at least as accurate, precise, and certain as the conventionally derived estimates. 2D-LCM estimation of frequency and phase correction and amplitudes performed substantially better at low-to-very-low SNR. ConclusionModel-based FPC with 2D linear-combination modeling is feasible and has great potential to improve metabolite level estimation for conventional and dynamic MRS data, especially for low-SNR conditions, e.g., long TEs or strong diffusion weighting.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISShamaei '22Ma '21Zöllner '24Ma '23Lee '26Siviglia '26
72% semantic matchNeuroscience
Amirmohammad Shamaei, Jana Starčuková, Iveta Pavlova+1 more·Magnetic Resonance in Medicine·Nov 11, 2022· 23 citations