Romer-EPTI: rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale dMRI and microstructure imaging
Zijing DongiD, Timothy G. ReeseiD, Hong‐Hsi LeeiD, Susie Y. HuangiD, Jon̈athan R. PolimeniiD, Lawrence L. WaldiD, Fuyixue WangiD
Abstract
PurposeTo overcome the major challenges in dMRI acquisition, including low SNR, distortion/blurring, and motion vulnerability. MethodsA novel Romer-EPTI technique is developed to provide distortion-free dMRI with significant SNR gain, high motion-robustness, sharp spatial resolution, and simultaneous multi-TE imaging. It introduces a ROtating-view Motion-robust supEr-Resolution technique (Romer) combined with a distortion/blurring-free EPTI encoding. Romer enhances SNR by a simultaneous multi-thick-slice acquisition with rotating-view encoding, while providing high motion-robustness through a motion-aware super-resolution reconstruction, which also incorporates slice-profile and real-value diffusion, to resolve high-isotropic-resolution volumes. The in-plane encoding is performed using distortion/blurring-free EPTI, which further improves effective spatial resolution and motion robustness by preventing not only T2/T2*-blurring but also additional blurring resulting from combining encoded volumes with inconsistent geometries caused by dynamic distortions. Self-navigation was incorporated to enable efficient phase correction. Additional developments include strategies to address slab-boundary artifacts, achieve minimal TE for SNR gain at 7T, and achieve high robustness to strong phase variations at high b-values. ResultsUsing Romer-EPTI, we demonstrate distortion-free whole-brain mesoscale in-vivo dMRI at both 3T (500-m-iso) and 7T (485-m-iso) for the first time, with high SNR efficiency (e.g., [Formula]), and high image quality free from distortion and slab-boundary artifacts with minimal blurring. Motion experiments demonstrate Romer-EPTIs high motion-robustness and ability to recover sharp images in the presence of motion. Romer-EPTI also demonstrates significant SNR gain and robustness in high b-value (b=5000s/mm2) and time-dependent dMRI. ConclusionRomer-EPTI significantly improves SNR, motion-robustness, and image quality, providing a highly efficient acquisition for high-resolution dMRI and microstructure imaging.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 28
- FWCI
- 5.63
- Field percentile
- top 2%
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging
Zijing Dong, Lawrence L. Wald, … Fuyixue Wang·Magnetic Resonance in MedicinePeer-reviewed·Oct 20, 2024
- SNR-efficient distortion-free diffusion relaxometry imaging using ACcelerated Echo-train shifted EPTI (ACE-EPTI)
Z. Dong, F. Wang, … K. Setsompop·bioRxiv·Aug 27, 2021
- High-SNR Whole-Brain Mesoscale Diffusion MRI Using Rotating-View Acquisitions (ROVER-dMRI)
Qiang Liu, Yunqi Wang, … Yogesh Rathi A·bioRxiv·Oct 1, 2026
- Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions
Anna I. Blazejewska, Thomas Witzel, … Jon̈athan R. Polimeni·NeuroImagePeer-reviewed·Oct 23, 2022
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging
Nan Wang, Congyu Liao, … Kawin Setsompop·Magnetic Resonance in MedicinePeer-reviewed·Sep 9, 2024
- Advancing High-Resolution 7T Diffusion MRI: Evaluating Phase-Encoding Correction Strategies for Distortion Correction from Basic to Four-Way Acquisitions
Kurt G. Schilling, Alexander J. S. Beckett, … An T. Vu·Magnetic Resonance ImagingPeer-reviewed·Apr 17, 2026