Blood-brain barrier water exchange measurements using contrast-enhanced ASL
E. Powell, B. R. Dickie, Y. Ohene, G. J. Parker, L. M. Parkes
Abstract
A technique for quantifying regional blood-brain barrier (BBB) water exchange rates using contrast-enhanced arterial spin labelling (CE-ASL) is presented and evaluated in simulations and in vivo. The two-compartment ASL model describes the water exchange rate from blood to tissue, kb, but to estimate kb in practice it is necessary to separate the intra- and extravascular signals. This is challenging in standard ASL data owing to the small difference in T1 values. Here, a gadolinium-based contrast agent is used to increase this T1 difference and enable the signal components to be disentangled. The optimal post-contrast blood T1 [Formula] at 3T was determined in a sensitivity analysis, and the accuracy and precision of the method quantified using Monte Carlo simulations. Proof-of-concept data were acquired in six healthy volunteers (five female, age range 24 - 46 years). The sensitivity analysis identified the optimal [Formula] at 3T as 0.8 s. Simulations showed kb could be estimated in individual cortical regions with a relative error{epsilon} < 1% and coefficient of variation CoV = 30 %; however, a high dependence on blood T1 was also observed. In volunteer data, mean parameter values in grey matter were: arterial transit time tA = 1.15{+/-}0.49 s, cerebral blood flow f = 58.0{+/-}14.3 ml blood / min / 100 ml tissue, water exchange rate kb = 2.32 {+/-} 2.49 s-1. CE-ASL can provide regional BBB water exchange rate estimates; however, the clinical utility of the technique is dependent on the achievable accuracy of measured T1 values.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Designing and Comparing Optimised Pseudo-Continuous Arterial Spin Labelling Protocols for Measurement of Cerebral Blood Flow
Joseph G. Woods, Michael A. Chappell, Thomas W. Okell·NeuroImagePeer-reviewed·Aug 24, 2020
- Feasibility of high-resolution perfusion imaging using Arterial Spin Labelling MRI at 3 Tesla
Sriranga Kashyap, Icaro Agenor Ferreira de Oliveira, Kâmil Uludaǧ·Frontiers in PhysiologyPeer-reviewed·Jan 3, 2024
- Velocity-selective arterial spin labelling bolus duration measurements: Implications for consensus recommendations
Ian D. Driver, Hannah Louise Chandler, … Michael A. Germuska·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- A dynamically coupled kinetic model for Arterial Spin Labeling: Enhancing the reliability of ventricular cerebrospinal fluid renewal quantification in vivo
Qiong Ye·bioRxiv·Aug 3, 2026
- Vascular-water-exchange MRI (VEXI) enables the detection of subtle BBB breakdown in Alzheimer's disease without MRI contrast agent
Yifan Zhang, Yue Wang, … Ruiliang Bai·bioRxiv·Sep 27, 2022
- Arterial blood contrast (ABC) enabled by magnetization transfer (MT): a novel MRI technique for enhancing the measurement of brain activation changes
Jenni Schulz, Zahra A. Fazal, … David Gordon Norris·bioRxiv·May 20, 2020