Radiance-Invariance Evaluation of a Compact LED-Based Source for Imager Radiance Transfer
Abstract
Significance: Fluorescence imaging remains largely qualitative and device-specific, limiting reproducibility and intersystem comparisons. SI-traceable radiometric characterization requires calibrated sources suitable for transferring known radiance to imaging systems. Aim: Establish and evaluate a compact, calibrated solid-state radiometric emitter target (RET) for SI-traceable radiance transfer, and assess methods for evaluating radiance invariance, imager responsivity, and extension of radiance transfer to digitally defined regions of interest (ROIs). Approach: The radiance invariance of an LED-based RET was evaluated by measuring its radiance across varying source-to-aperture distances and collection apertures. A previously described radiance-transfer formalism based on calibrated source radiance and collection geometry was implemented to determine imager responsivity (R{lambda}), which was evaluated across varying working distances and lens apertures. Grubbs and MAD outlier tests and one-way ANOVA were used to assess radiance and responsivity invariance. Finally, responsivity obtained using digitally defined ROIs was compared with matched physical apertures to assess ROI-based radiance transfer. Results: The measured RET radiance remained invariant across the tested source-to-aperture distances and collection apertures, with no significant differences observed across distance (p = 0.88) or aperture (p = 0.15). Imager responsivity remained stable across working distances for both tested lens configurations (p = 0.48 and p > 0.99). Responsivity was also invariant across lens apertures, except for deviations at f/11 that were consistent with practical aperture tolerances. Digitally defined ROIs reproduced responsivity values obtained using matched physical apertures, demonstrating that the radiance-transfer approach can be extended to image-defined regions. Conclusions: The presented methods provide an approach for evaluating compact LED-based sources for invariant-radiance emission and suitability for SI-traceable radiance transfer. The characterized RET supported stable imager responsivity across changes in imaging geometry and extension to digitally defined ROIs. These methods can be adapted to other LED-based sources, with further angular characterization and uncertainty analysis needed to establish broader applicability.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Quantitative Fluorescence Imaging with SI-Traceable Radiance: Radiometric Fluorescence Characterization with a Calibrated Solid-State Emitter
Alberto J. Ruiz, Edwin A. Robledo, Eammon A. Littler·bioRxiv·Oct 15, 2025
- Computational Luminance Constancy from Naturalistic Images
Vijay Singh, Nicolas P. Cottaris, … Johannes Burge·Journal of VisionPeer-reviewed·Dec 28, 2018
- Invariant categorical color regions across illuminant change coincide with focal colors
Takuma Morimoto, Yasuki Yamauchi, Keiji Uchikawa·Journal of VisionPeer-reviewed·Feb 13, 2023
- The effect of illumination cues on color constancy in simultaneous identification of illumination and reflectance changes
Lari S. Virtanen, Maria Olkkonen, Toni Saarela·Journal of VisionPeer-reviewed·May 6, 2025
- Characterization of human lightness discrimination thresholds for independent spectral variations
D. J. Reynolds, V. Singh·bioRxiv·Jun 16, 2023
- When the brightest is not the best: illuminant estimation from the geometry of specular highlights
Takuma Morimoto, Robert J. Lee, Hannah E. Smithson·Proceedings of the Royal Society B Biological SciencesPeer-reviewed·Aug 5, 2026