A public-data reproducibility benchmark of a 2.5-D U-Net with a slice-level topology term for type-B aortic dissection segmentation

Lingsen YouiD, Yujun Guo, Xinyu Zhong, Zisu Peng, Wentong WangiD, Li Shen, Junbo GeiD

Abstract

Background: Type-B aortic dissection requires separation of the true and false lumina in heterogeneous, anisotropic CTA. A topology term may reduce fragmentation, but its reproducibility must be tested under a fixed case split and independent native-grid evaluation. Methods: We used the public Graz type-B aortic dissection CTA collection (40 cases; CC BY 4.0) and froze a 28/6/6 case split for training, development, and held-out testing. A compact 2.5-D U-Net trained with cross-entropy plus multiclass Dice was compared with the identical model augmented by a fixed-weight (0.5) differentiable slice-level soft clDice term. Two training seeds were run for each arm. All 40 cases passed the NRRD audit; predictions for six held-out cases were restored to their native grids and scored with case-level 3-D voxel-grid Dice, voxel-grid morphological clDice, 6-connected component counts, physical-volume error, and 2,000-resample case-level paired bootstrap intervals. Results: With seed 20261007, topology-minus-baseline differences were -0.028 (95% CI -0.053 to -0.004) for true-lumen Dice, +0.032 (-0.006 to +0.096) for true-lumen voxel-grid clDice, +0.071 (+0.037 to +0.103) for false-lumen Dice, and +0.073 (+0.048 to +0.103) for false-lumen voxel-grid clDice. With seed 20261008, the corresponding differences were -0.040 (-0.065 to -0.018), +0.013 (-0.034 to +0.071), -0.099 (-0.187 to -0.004), and -0.058 (-0.124 to -0.001). Descriptive pooled means over 12 case rows per arm were true-lumen Dice 0.577 for topology versus 0.611 for baseline and false-lumen Dice 0.409 versus 0.422; these pooled rows are not independent cases. Conclusions: Under this fixed six-case test split, the corrected slice-level topology term did not produce a consistent benefit. True-lumen Dice was lower in both seeds, while false-lumen effects reversed direction between seeds; topology-clDice changes were small and/or interval-crossing. The benchmark supports an auditable failure-analysis workflow but does not support a general topology benefit, clinical use, external generalization, or a panvascular decision system.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.