EDoF-Miniscope: pupil engineering for extended depth-of-field imaging in a fluorescence miniscope
J. Greene, Y. Xue, J. Alido, A. Matlock, G. Hu, K. Kilic, I. G. Davison, L. Tian
Abstract
Extended depth of field (EDoF) microscopy has emerged as a powerful solution to greatly increase the access into neuronal populations in table-top imaging platforms. Here, we present EDoF-Miniscope, which integrates an optimized thin and lightweight binary diffractive optical element (DOE) onto the gradient refractive index (GRIN) lens of a head-mounted fluorescence miniature microscope, i.e. "miniscope". We achieve an alignment accuracy of 70 m to allow a 2.8X depth-of-field extension between the twin foci. We optimize the phase profile across the whole back aperture through a genetic algorithm that considers the primary GRIN lens aberrations, optical property of the submersion media, and axial intensity loss from tissue scattering in a Fourier optics forward model. Compared to other computational miniscopes, our EDoF-Miniscope produces high-contrast signals that can be recovered by a simple algorithm and can successfully capture volumetrically distributed neuronal signals without significantly compromising the speed, signal-to-noise, signal-to-background, and maintain a comparable 0.9-m lateral spatial resolution and the size and weight of the miniature platform. We demonstrate the robustness of EDoF-Miniscope against scattering by characterizing its performance in 5-m and 10-m beads embedded in scattering phantoms. We demonstrate that EDoF-Miniscope facilitates deeper interrogations of neuronal populations in a 100-m thick mouse brain sample, as well as vessels in a mouse brain. Built from off-the-shelf components augmented by a customizable DOE, we expect that this low-cost EDoF-Miniscope may find utility in a wide range of neural recording applications.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Extended field-of-view ultrathin microendoscopes for high-resolution two-photon imaging with minimal invasiveness in awake mice
Andrea Antonini, Andrea Sattin, … Tommaso Fellin·eLifePeer-reviewed·Oct 13, 2020
- Deep brain fluorescence imaging with minimally invasive ultra-thin optical fibers
Shay Ohayon, Antonio M. Caravaca-Aguirre, … James J. DiCarlo·bioRxiv·Mar 16, 2017
- Maximized field-of-view deep-brain calcium imaging through gradient-index lenses
Chenmao Wang, Zongyue Cheng, … Meng Cui·bioRxiv·Sep 8, 2025
- Large-scale calcium imaging with a head-mount axial scanning 3D fluorescence microscope
Yuichiro Hayashi, Ko Kobayakawa, Reiko Kobayakawa·bioRxiv·Jan 20, 2021
- Aberration correction in long GRIN lens-based microendoscopes for extended field-of-view two-photon imaging in deep brain regions
Andrea Sattin, Chiara Nardin, … Tommaso Fellin·eLifePeer-reviewed·May 2, 2025
- Focus-tunable microscope for imaging small neuronal processes in freely moving animals
Arutyun Bagramyan, Loïc Tabourin, … Tigran Galstian·Photonics ResearchPeer-reviewed·Apr 5, 2021