Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging
Andrew S WeitziD, Hatim Belgharbi, Masashi Sode, Rebecca M Jones-Sinnott, Rohit NayakiD, Trevor Fochtman, Mikhail G. ShapiroiD, Paul A Dayton, Gianmarco F Pinton
Abstract
Cross-amplitude modulation (xAM) is a commonly used pulse sequence for non-destructive, quasi-artifact-free detection of gas-vesicle (GV) contrast agents, but it has so far been limited to two-dimensional cross-sections acquired with one-dimensional linear arrays. We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32x32-element Vermon probe (7.81 MHz, 300 m element pitch). Angular spectrum simulations compared three primary bisections (X-axis, Y-axis, and diagonal (D1,D2)), and the selected Y-split was tested experimentally in GV-loaded tissue-mimicking phantoms. We also simulated an electronic asymmetric-angle sweep as an alternative to the robotic translation used in the experiments, and measured contrast through an ex vivo mouse skull. The non-emissive regions between the elevation panels of the Vermon probe accounted for most of the simulated differences among partitions, through both the continuity of the aperture parallel to the bisector plane and the side-lobe structure. At a 6 degree steering angle, the Y-split gave a contrast-to-tissue ratio (CTR) of ~29 dB for single frames and ~49 dB with 100-frame averaging without the skull, and a contrast-to-noise ratio (CNR) of ~8 dB for single frames and ~12 dB with 100-frame averaging through the skull, where the inclusion remained resolvable. These results give design rules for xAM on matrix arrays. The through-skull result comes from a single ex vivo specimen, and in vivo work is the next step toward non-invasive, longitudinal, three-dimensional monitoring of GV-labeled glioblastoma and other targets of nonlinear contrast agents.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Harmonic imaging for nonlinear detection of acoustic biomolecules
Rohit Nayak, Mengtong Duan, … Mikhail G. Shapiro·APL BioengineeringPeer-reviewed·Nov 12, 2024
- Nonlinear Singular Value Decomposition Beamforming for Ultrasound Imaging of Gas Vesicles
Ge Zhang, Mathis Vert, … Mickaël Tanter·IEEE Transactions on Medical ImagingPeer-reviewed·Apr 28, 2025
- Harmonic Amplitude-Modulated Singular Value Decomposition for Ultrafast Ultrasound Imaging of Gas Vesicles
Ge Zhang, Henri Leroy, … Mickaël Tanter·bioRxiv·Jul 21, 2025
- A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging
R. P. Xian, J. Brunet, … C. L. Walsh·bioRxiv·Feb 14, 2023
- Characterisation of Gas Vesicles as Cavitation Nuclei for Ultrasound Therapy using Passive Acoustic Mapping
Cameron A. B. Smith, Avinoam Bar‐Zion, … Constantin C. Coussios·AIP AdvancesPeer-reviewed·Feb 1, 2025
- Methacrylate-Modified Gold Nanoparticles Enable Non-Invasive Monitoring of Photocrosslinked Hydrogel Scaffolds
L. Li, C. J. Gil, … R. K. Roeder·bioRxiv·Jan 26, 2022