Using force data to self-pace an instrumented treadmill and measure self-selected walking speed
Abstract
BackgroundSelf-selected speed is an important functional index of walking. A self-pacing controller that reliably matches walking speed without additional hardware can be useful for measuring self-selected speed in a treadmill-based laboratory. MethodsWe adapted a previously proposed self-pacing controller for force-instrumented treadmills and validated its use for measuring self-selected speeds. We first evaluated the controllers estimation of subject speed and position from the force-plates by comparing it to those from motion capture data. We then compared five tests of self-selected speed. Ten healthy adults completed a standard 10-meter walk test, a 150-meter walk test, a commonly used manual treadmill speed selection test, a two-minute self-paced treadmill test, and a 150-meter self-paced treadmill test. In each case, subjects were instructed to walk at or select their comfortable speed. We also assessed the time taken for a trial and a survey on comfort and ease of choosing a speed in all the tests. ResultsThe self-pacing algorithm estimated subject speed and position accurately, with root mean square differences compared to motion capture of 0.023 m s-1 and 0.014 m, respectively. Self-selected speeds from both self-paced treadmill tests correlated well with those from the 10-meter walk test (R > 0.93, p < 1 x 10-13). Subjects walked slower on average in the self-paced treadmill tests (1.23 {+/-} 0.27 m s-1) than in the 10-meter walk test (1.32 {+/-} 0.18 m s-1) but the speed differences within subjects were consistent. These correlations and walking speeds are comparable to those from the manual treadmill speed selection test (R = 0.89, p = 3 x 10-11; 1.18 {+/-} 0.24 m s-1). Comfort and ease of speed selection were similar in the self-paced tests and the manual speed selection test, but the self-paced tests required only about a third of the time to complete. Our results demonstrate that these self-paced treadmill tests can be a strong alternative to the commonly used manual treadmill speed selection test. ConclusionsThe self-paced force-instrumented treadmill well adapts to subject walking speed and reliably measures self-selected walking speeds. We provide the self-pacing software to facilitate use by gait researchers and clinicians.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Self-paced treadmill controller algorithm based on position and speed of centre of mass
H. Mokhtarzadeh, R. Richards, T. Geijtenbeek·bioRxiv·Jun 21, 2022
- Auditory feedback effect of self-pacing treadmill walking in comparison to overground walking
Trevor V. Evans, Megan E. Reissman, … Ajit M.W. Chaudhari·PLoS ONEPeer-reviewed·Nov 4, 2025
- Speed-related but not detrended gait variability increases with more sensitive self-paced treadmill controllers at multiple slopes
C. R. Castano, H. J. Huang·bioRxiv·Jan 27, 2021
- Walking speed can be modulated on an adaptive split-belt treadmill
Rucha Kulkarni, Barry Bodt, Jill S. Higginson·Applied SciencesPeer-reviewed·Sep 16, 2026
- Self-paced treadmills do not allow for valid observation of linear and non-linear gait variability outcomes in patients with Parkinson's disease.
Maryam Rohafza, Rahul Soangra, … Niklas König·Gait & PosturePeer-reviewed·Oct 9, 2021
- On attaining and estimating steady walking speed
Jeremy D. Wong, Osman Darici, Arthur D. Kuo·bioRxiv·Mar 3, 2026